E3S Web of Conferences (Jan 2020)
Possible in-service damages of steam generators at VVER-1000 and VVER-1200 NPP units and their impact on long-term operation
Abstract
Specific features of corrosion-mechanical damages of primary circuit header to steam generator vessel branch welds at VVER-1000 NPPs and their impact on safety and economic efficiency during long-term operation are analysed. Measures to avoid the damages for similar zones of VVER-1200 steam generators are discussed.
Keywords