Applied Sciences (Apr 2024)
Study on Temperature Characteristics of Lubrication Film of Valve Plate Pair in Axial Piston Pumps
Abstract
The film temperature distribution of the valve plate pair in axial piston pumps affects its lubrication, leakage, and friction. In order to investigate the film temperature distribution of the valve plate pair in axial piston pumps, a test platform was constructed including three displacement sensors for the oil film thickness and eleven thermocouples for the film temperature distribution of the valve plate pair. An accurate film shape model of the valve plate pair was built according to the three-point film thickness test data. Based on the film shape model, the film temperature model of the valve plate pair was developed considering the viscous oil temperature characteristics, the energy loss caused by leakage and viscous friction in the film, and the heat conduction among the oil, cylinder block, and valve plate. The influence of different swash plate tilt angles and operating pressures on the valve plate film temperature was studied. The test results indicate that the film temperature of the valve plate pair increases as the working pressure and swash plate tilt angle increase. The theoretical and experimental absolute errors of the film temperature in the circumferential range [−60°, 60°] of the valve plate high-pressure side are less than 3.5 °C. As the swash plate tilt angle varies from 12° to 16° and working pressure from 3 MPa to 7 MPa, the minimum film thickness position and the maximum temperature point move accordingly in the circumferential range [−15°, 5°] of the valve plate pair.
Keywords