Applied Sciences (Sep 2020)

Transcatheter Tricuspid Valve-in-Valve Replacement by Transatrial Approach

  • Grigore Tinica,
  • Igor Nedelciuc,
  • Iulian Rotaru,
  • Flavia Catalina Corciova,
  • Dumitru Grajdianu,
  • Andrei Tarus,
  • Mihail Enache,
  • Raluca Ozana Chistol,
  • Maria Luiza Cobzeanu,
  • Cristina Furnica

DOI
https://doi.org/10.3390/app10186540
Journal volume & issue
Vol. 10, no. 18
p. 6540

Abstract

Read online

Reoperation on the tricuspid valve after prior heart valve surgery is associated with an increased operative risk due to a poor clinical status with severe heart failure and late presentation. Transcatheter tricuspid valve-in-valve implantation emerged as an attractive alternative to a high-risk redo surgery. The authors report a case of successful treatment of a failed bioprosthetic tricuspid valve in a 58-year-old woman with severe heart failure, decompensated cardiac cirrhosis and atrial fibrillation using transcatheter tricuspid valve-in-valve implantation of a Sapien 3 valve (Edwards Lifesciences, Irvine, California) via a transatrial approach. This case demonstrates the efficiency of this novel approach for the treatment of dysfunctional surgical tricuspid bioprosthetic valves and the technical feasibility and safety of a rarely used route.

Keywords