International Journal of Nephrology and Renovascular Disease (Mar 2020)

Assessing Renal Microvascular Reactivity by Laser Speckle-Contrast Imaging in Angiotensin-II-Treated Mice

  • Mottard N,
  • Berkowitz DE,
  • Santhanam L

Journal volume & issue
Vol. Volume 13
pp. 45 – 51

Abstract

Read online

Nicolas Mottard,1,2 Dan E Berkowitz,1,3 Lakshmi Santhanam1,3 1Department of Anesthesiology and Critical Care Medicine, Johns Hopkins University School of Medicine, Baltimore, MD, USA; 2Department of Anesthesiology and Critical Care, Clinique de la Sauvegarde, Ramsay Santé, Lyon, France; 3Department of Biomedical Engineering, Johns Hopkins University, Baltimore, MD, USACorrespondence: Nicolas Mottard Tel +33 682054902Email [email protected]: The kidney is one of the main organs affected by microvascular damage wrought by hypertension. We developed an approach to investigate renal microcirculatory disturbance in live mice by measuring post-occlusive reactive hyperemia (PORH), a reactivity test exploring endothelial and neuro-microvascular functioning. Laser speckle-contrast analysis (LASCA) assesses microvascular blood flow; it provides real-time images of spatial and temporal blood flow dynamics. We compared basal blood flow and PORH test between control and angiotensin-II-treated mice (Ang-II) to validate the model.Objective: The study objective was to develop an approach to investigate renal microcirculation, and then to compare microvascular reactivity assessed on LASCA in control versus Ang-II mice.Methods: Thirty 7-week-old wild-type C57BL/6J mice were allocated into two groups. One received angiotensin-II via osmotic minipumps (Ang-II; n=15); the other served as control (n=15). Basal blood flow was measured on LASCA. The PORH test was then performed in the two groups.Results: Control mice had significantly lower basal renal microcirculatory flow, expressed in perfusion units (PU), than Ang-II-treated mice (1448 ± 96 vs 1703 ± 185 PU, respectively; P < 0.05). Peak flow was lower in controls than in Ang-II mice (1617± 104 vs.1724 ± 205 PU, respectively; P=0.21). Control mice had significantly higher kidney PORH than Ang-II mice (8± 3 vs 1± 4%, respectively; P < 0.05).Conclusion: We developed an innovative technique to study renal microcirculation in mice. Ang-II-treated mice showed significantly higher basal blood flow than controls, while PORH was significantly higher in controls than in Ang-II mice.Keywords: microvascular reactivity, laser speckle-contrast analysis, hypertension, renal microcirculation

Keywords