Experiência inicial no fechamento percutâneo da comunicação interatrial com a prótese de Amplatzer Initial experience in percutaneous occlusion of atrial septal defects with the Amplatzer device

  • Valmir F. Fontes,
  • Carlos A. C. Pedra,
  • Simone R. F. Fontes Pedra,
  • César A. Esteves,
  • Sérgio L. N. Braga,
  • Jorge E. Assef,
  • Sérgio C. Pontes Jr,
  • Maria Virgínia T. Santana,
  • Ziyad M. Hijazi,
  • J. Eduardo M. R. Sousa

DOI
https://doi.org/10.1590/S0066-782X1998000300002
Journal volume & issue
Vol. 70, no. 3
pp. 147 – 153

Abstract

Read online

OBJETIVO: Analisar a experiência inicial no fechamento percutâneo da comunicação interatrial ostium secundum (CIA OS) com a prótese de Amplatzer. MÉTODOS: Sete pacientes foram submetidos ao procedimento através da via venosa anterógrada, orientados pela ecocardiografia transesofágica (ETE) e sob anestesia geral. Uma criança era portadora de 2 CIA e de canal arterial (CA). As CIA medidas pelo ETE variaram de 8,7 a 20mm. Um ecocardiograma transtorácico foi realizado na manhã seguinte do procedimento. RESULTADOS: Oito próteses foram implantadas nos 7 pacientes com sucesso. Em um paciente, o CA foi ocluído na mesma sessão com mola de Gianturco, tendo surgido taquicardia supraventricular durante a oclusão de uma das CIA, controlada com adenosina. Todos receberam alta hospitalar na manhã seguinte, com oclusão total dos defeitos. CONCLUSÃO: O procedimento mostrou-se seguro, eficaz e versátil, podendo ser considerado como uma alternativa terapêutica inicial em pacientes selecionados com CIA OS.PURPOSE: To evaluate our initial experience with percutaneous closure of secundum type atrial septal defects (ASD) with the Amplatzer septal occluder. METHODS: Seven patients underwent occlusion by anterograde approach, under general anesthesia and transesophageal echocardiography (TEE) guidance. One child had 2 ASD and a patent ductus arteriosus (PDA). The ASD size ranged from 8,7 to 20mm as measured by TEE. A transthoracic echocardiogram was performed in the morning after the procedure. RESULTS: Eight devices were successfully implanted in 7 patients and the PDA was occluded with a Gianturco coil at the same session. In this patient, there was an episode of supraventricular tachycardia during the occlusion of one ASD which was reverted with adenosin. All patients were discharged the day after, with complete occlusion of all defects. CONCLUSION: The procedure is safe, effective and versatile. It can be applied as an initial alternative to the treatment of selected patients with ASD.

Keywords