Journal of Dental Research, Dental Clinics, Dental Prospects (Mar 2020)
Effect of preheating on the cytotoxicity of bulk-fill composite resins
Abstract
Background. Due to the effect of pre-heating on the degree of conversion of composite resins and the possible effect on cytotoxicity, the effect of pre-heating of bulk-fill composite resins was investigated on cytotoxicity in this study. Methods. In this study, three different types of composite resin were used, including Tetric N-Ceram Bulk-Fil, Xtrafil, and Xtrabase. From each composite resin, 10 cylindrical samples (5 mm in diameter and 4 mm in height) were prepared, with five samples preheated to 68°C, and the other five samples polymerized at room temperature (25°C). Twenty-four hours after polymerization, cytotoxicity was assessed by MTT assay on human fibroblasts. Statistical analysis of data was carried out with two-way ANOVA and Sidak Post-Hoc. The significance level of the test was determined at 0.05. Results. There was no statistically significant difference between the mean percentage of cytotoxicity in terms of pre-heating (P>0.05), but the cytotoxicity of the studied composite resins was significantly different (P<0.001). The cytotoxicity of Tetric N-Ceram Bulk-fil composite resin was higher than that of the two other composite resins. Conclusion. Pre-heating of bulk-fill composite resin did not affect their cytotoxicity. In addition, the cytotoxicity of different bulk-fill composite resins was not the same.
Keywords