Structural Mechanics of Engineering Constructions and Buildings (Mar 2024)

Seismic Performance Evaluation of Multi-Storey Residential Building with Friction Pendulum Bearings: Indonesia case study

  • Zaurbek K. Abaev,
  • Faiz Sulthan

DOI
https://doi.org/10.22363/1815-5235-2024-20-1-57-72
Journal volume & issue
Vol. 20, no. 1
pp. 57 – 72

Abstract

Read online

The methodology for seismic performance evaluation of a residential building in Indonesia with the use of seismic isolation is considered. An 8-storey reinforced concrete frame residential building with shear wall structural system was selected as a case study. Nonlinear methods of seismic response analysis were used to calculate the response of the structure: nonlinear static (Pushover) and Nonlinear-Time History Analysis, NLTHA. The analysis is performed in STERA 3D freeware. The nonlinear time history analysis was performed for seven pairs of horizontal components of earthquake ground motions, selected according to the parameters of possible earthquakes for the considered site (Bandung city). The selected earthquake records were modified using the spectral matching procedure for design spectrum. Friction-pendulum bearings developed by Nippon Steel Corporation of Japan were used as seismic isolation. The results of nonlinear time history analysis show that shallow earthquakes result in greater damage compared to megathrust earthquakes, with both scenarios providing a life safety (LS) performance level. The use of seismic isolation can reduce seismic loads, as evidenced by the reduction in top-level accelerations and shear forces at the base.

Keywords