Sistemnyj Analiz i Prikladnaâ Informatika (Oct 2023)

Fea study of effectiveness of bionic legacy-shape console as huge machine tool’s column

  • S. S. Dounar,
  • V. K. Jatskevich,
  • A. M. Ausiyevich,
  • D. N. Shvedova,
  • I. Y. Aglushevich

DOI
https://doi.org/10.21122/2309-4923-2023-2-13-23
Journal volume & issue
Vol. 0, no. 2
pp. 13 – 23

Abstract

Read online

Concept of machine tool’s column in the appearance of vertical bionic console is proposed. Console was 3D-transformed from the shape of legacy oak-like structure – Eddystone lighthouse. It is proposed to create the variable-section column with “layer-by-layer” technics from the polymer concrete.FEA shows high stiffness of the column. It increases from 1500 to 11000 N/μm from top to bottom along vertical guideways. Such stiffness needs only 19.3 ton of concrete for the instance of 4.5 m height’s column. FEMmodelling pointed out rather high eigenmode’s frequencies (˃49 Hz). FRF is appropriate for pre-resonance heavy cutting as for post-resonance finishing. Proposed bionic-shape column is perspective as for stand-alone variant so for portal composition created by two opposite columns.

Keywords