Abstract Background Hemodialysis mainly relies on the “artificial kidney,” which plays a very important role in temporarily or permanently substituting for the kidney to carry out the exchange of waste and discharge of water. Nevertheless, a previous study on the artificial kidney has paid little attention to the optimization of factors and levels for reducing the solidification of the artificial kidney during the hemodialysis procedure. Thus, this study proposes an integrated model that uses the Taguchi method, omega formula, and back-propagation network to determine the optimal factors and levels for addressing this issue. Methods First, we collected the recommendations of medical doctors and nursing staff through a small group discussion, and used the Taguchi method to analyze the key factors at different levels. Next, the omega formula was used to convert the analysis results from the Taguchi method to assess the defect rate. Finally, we utilized back-propagation network algorithms to predict the optimal factors and levels for artificial kidney solidification, in order to confirm that the key factors and levels identified can effectively improve the solidification rate of the artificial kidney and thereby enhance the effect of hemodialysis. Results The research finding proposes the following as the optimal factors and levels for artificial kidney solidification: the amount of anticoagulation should be set at 500 units, the velocity of blood flow at 300 ml/min, the dehydration volume at 2.5 kg, and the vascular access type as autologous blood vessels. We obtained 270 sets of data from the patients of End Stage Renal Disease (ESRD) under the setting of the optimal combination of the factors at different levels; the defect rate of artificial kidney solidification is 12.9%, which is better than the defect rate of 32% in the original experiment. Meanwhile, the patient characteristics for physiological status in BMI, serum calcium, hematocrit, ferritin, and transferrin saturation percentage are improved by this study. Conclusion This conclusion validates the ability of the proposed model in this study to improve the solidification rate of the artificial kidney, thereby confirming the model’s use as a standard operation procedure in the hemodialysis experiment. The ideas behind and the implications of the proposed model are further discussed in this study.

Keywords