Journal of Pediatric Surgery Case Reports (Nov 2024)

Totally implantable venous access device (TIVAD) migration into the pleural space: A case report

  • Fatemeh Shahrahmani,
  • Reza Shojaeian

Journal volume & issue
Vol. 110
p. 102887

Abstract

Read online

Introduction: Totally implantable venous access devices (TIVADs) offer significant advantages for long-term intravenous therapy, but their use is not without potential complications. Catheter migration is one of them. Case presentation: An 11-year-old boy with a primitive neuro-ectodermal tumor (PNET) undergoing chemotherapy was a candidate for a TIVAD placement. A TIVAD was implanted through the right internal jugular vein and secured to the pectoralis major in a right thoracic subcutaneous pouch without complications. Approximately six months later, port malfunction was noticed. Physical examination revealed that the port was no longer palpable, and a chest X-ray confirmed that the port was displaced. Subsequent chest X-rays showed different locations of the port and the catheter. With the hypothesis that the port had entered the pleural space and was moving freely, we did an exploratory thoracoscopy. We confirmed the intrapleural position of the port and catheter and removed both without complications. The patient was discharged four days later. Conclusion: Although rare, TIVADs can migrate from the chest wall into the pleural cavity. Frequent evaluation of their function and position is critical for the early detection of complications.

Keywords