Cancer Imaging (Jan 2024)

Contrast-enhanced CT radiomics features to preoperatively identify differences between tumor and proximal tumor-adjacent and tumor-distant tissues of resectable esophageal squamous cell carcinoma

  • Dan Gao,
  • Bang-guo Tan,
  • Xiao-qian Chen,
  • Chuanqinyuan Zhou,
  • Jing Ou,
  • Wen-wen Guo,
  • Hai-ying Zhou,
  • Rui Li,
  • Xiao-ming Zhang,
  • Tian-wu Chen

DOI
https://doi.org/10.1186/s40644-024-00656-0
Journal volume & issue
Vol. 24, no. 1
pp. 1 – 13

Abstract

Read online

Abstract Background Esophagectomy is the main treatment for esophageal squamous cell carcinoma (ESCC), and patients with histopathologically negative margins still have a relatively higher recurrence rate. Contrast-enhanced CT (CECT) radiomics might noninvasively obtain potential information about the internal heterogeneity of ESCC and its adjacent tissues. This study aimed to develop CECT radiomics models to preoperatively identify the differences between tumor and proximal tumor-adjacent and tumor-distant tissues in ESCC to potentially reduce tumor recurrence. Methods A total of 529 consecutive patients with ESCC from Centers A (n = 447) and B (n = 82) undergoing preoperative CECT were retrospectively enrolled in this study. Radiomics features of the tumor, proximal tumor-adjacent (PTA) and proximal tumor-distant (PTD) tissues were individually extracted by delineating the corresponding region of interest (ROI) on CECT and applying the 3D-Slicer radiomics module. Patients with pairwise tissues (ESCC vs. PTA, ESCC vs. PTD, and PTA vs. PTD) from Center A were randomly assigned to the training cohort (TC, n = 313) and internal validation cohort (IVC, n = 134). Univariate analysis and the least absolute shrinkage and selection operator were used to select the core radiomics features, and logistic regression was performed to develop radiomics models to differentiate individual pairwise tissues in TC, validated in IVC and the external validation cohort (EVC) from Center B. Diagnostic performance was assessed using area under the receiver operating characteristics curve (AUC) and accuracy. Results With the chosen 20, 19 and 5 core radiomics features in TC, 3 individual radiomics models were developed, which exhibited excellent ability to differentiate the tumor from PTA tissue (AUC: 0.965; accuracy: 0.965), the tumor from PTD tissue (AUC: 0.991; accuracy: 0.958), and PTA from PTD tissue (AUC: 0.870; accuracy: 0.848), respectively. In IVC and EVC, the models also showed good performance in differentiating the tumor from PTA tissue (AUCs: 0.956 and 0.962; accuracy: 0.956 and 0.937), the tumor from PTD tissue (AUCs: 0.990 and 0.974; accuracy: 0.952 and 0.970), and PTA from PTD tissue (AUCs: 0.806 and 0.786; accuracy: 0.760 and 0.786), respectively. Conclusion CECT radiomics models could differentiate the tumor from PTA tissue, the tumor from PTD tissue, and PTA from PTD tissue in ESCC.

Keywords