Physical Review Special Topics. Accelerators and Beams (Sep 2002)

Transient beam loading effects in harmonic rf systems for light sources

  • J. M. Byrd,
  • S. De Santis,
  • J. Jacob,
  • V. Serriere

DOI
https://doi.org/10.1103/PhysRevSTAB.5.092001
Journal volume & issue
Vol. 5, no. 9
p. 092001

Abstract

Read online Read online

Harmonic cavities have been used in storage rings to lengthen bunches and increase beam lifetimes dominated by Touschek scattering. Transient beam loading in the harmonic cavities generated by asymmetries in the fill pattern causes significant variation of the bunch synchronous phase and bunch length along the bunch train when the longitudinal restoring force has been reduced. This results in a significant reduction in the mean bunch lengthening and potential lifetime increase. We describe how beam current modulations give rise to transient effects much larger than expected from the linear model of the beam cavity interaction. We also develop a tracking simulation to predict results and apply this simulation to an analysis of the beam loading transients for the case of passive and active normal and superconducting third harmonic rf systems using Advanced Light Source parameters.