Scientific Reports (Jan 2022)
The oblique triangle configuration of three parallel screws for femoral neck fracture fixation using computer-aided design modules
Abstract
Abstract Closed reduction and internal fixation with three cannulated compression screws is a common method for treating femoral neck fractures in young and middle-aged patients. Protocols including the inverted triangle configuration and dispersion of the screws still needed further supports. The purpose of this study was to explore a novel oblique triangle configuration (OTC) of three screws in fixing femoral neck fractures based on the morphology of the femoral neck isthmus (FNI). The computer-aided design modules were used to explore the ideal spatial configuration with largest triangle by three parallel screws. A univariate evaluation model was established based on the oval-like cross-section of the FNI. When the three screws were positioned by the OTC, Inverted Equilateral Triangle Configuration (IETC), and the Maximum Area Inverted Isosceles Triangle Configuration (MA-IITC) respectively, the proportion of area and circumference in the cross-section of FNI and the changing trend of proportion were compared under various torsion angles, eccentricity, and cross-sectional area of FNI. The area and circumference ratios of the parallel screws using the OTC method were significantly higher than in the IETC and MA-IITC groups. In the univariate evaluation model, the OTC area ratio and circumference ratio remained stable under the different femoral neck torsion angles, FNI cross-sectional area, and eccentricity. The OTC method provided an ideal spatial configuration for the FNA fixation with the largest area using three parallel screws. The position of the posterior screw was also away from the metaphyseal artery, potentially reducing the possibility of vascular injury and screw penetrating.