Case Studies in Thermal Engineering (Sep 2017)

Design and performance of a mechanically pumped two-phase loop to support the evaporation-condensation experiments on the TZ1

  • Z.R. Wang,
  • X.B. Zhang,
  • S.Z. Wen,
  • Z.C. Huang,
  • D.C. Mo,
  • Y.Q. Xue,
  • Z.H. He

DOI
https://doi.org/10.1016/j.csite.2017.11.008
Journal volume & issue
Vol. 10, no. C
pp. 650 – 655

Abstract

Read online

The mechanically pumped two-phase loop (MPTL) has the advantages of long distance heat transport, high heat density and good temperature control. On TZ1, the MPTL technology is adopted to support a series experiments of evaporation and condensation. The main objective is to provide accurate (±0.5 ℃) temperature control from −5 ℃ to 40 ℃ and remove 80 W heat from the experimental setup. In this paper, the requirements, system design, hardware and performance of the MPTL are introduced.

Keywords