Arquivos Brasileiros de Cardiologia (Jan 2007)
Efeitos da associação da estimulação atrial dinâmica em duplo sítio atrial com atenolol na prevenção da fibrilação atrial recorrente Effects of the association of dual-site dynamic atrial overdrive and atenolol in preventing recurrent atrial fibrillation
Abstract
OBJETIVO: Avaliar os efeitos da estimulação atrial otimizada (EAO) (estimulação duplo-sítio atrial, freqüência acima da intrínseca e algoritmo funcional específico) e uso de atenolol, na prevenção da fibrilação atrial (FA) recorrente. Desfecho primário: quantificar a taxa de episódios de FA. Desfechos secundários: qualidade de vida, avaliação de sintomas específicos cardiovasculares, taxa de internações hospitalares, taxa de cardioversões elétricas e farmacológicas e eventos cardíacos adversos. MÉTODOS: Vinte e sete pacientes com FA paroxística recorrente e doença do nó sinusal foram submetidos ao implante de marcapasso duplo-sítio atrial e ventricular e iniciaram com atenolol 100 mg/dia, a seguir foram randomizados em dois grupos, grupo I (3 meses iniciais com EAO e algoritmo especifico ligado e mais 3 com o mesmo desligado) e grupo II (seqüência inversa do grupo I). O modo de estimulação foi DDDR e após 3 meses, foram submetidos à avaliação clínica e eletrônica do sistema de estimulação - mudança automática de modo (AMS), Holter de 24 horas, ecocardiograma e questionário SF-36. Em seguida, foram cruzados e após 6 meses, nova avaliação. RESULTADOS: Pacientes com EAO, quando comparados ao grupo com algoritmo desligado, apresentaram menores taxas de: FA/semana (pOBJECTIVE: Evaluate the effects of optimized atrial stimulation - OAS (dual-site atrial pacing, heart rate above the intrinsic rate, and specific functional algorithm), and the use of atenolol in preventing recurrent atrial fibrillation (AF). Primary endpoint: to quantify the rate of AF episodes. Secondary endpoints: assessment of quality of life, specific cardiovascular symptoms, rate of hospital admissions, rate of electrical and pharmacological cardioversions, and adverse cardiac events. METHODS: Twenty-five patients with recurrent episodes of paroxysmal AF and sinus node disease had dual-site atrial and ventricular pacemakers implanted, and were started on atenolol, 100 mg/day. Next, they were randomized to two groups: GROUP I: first three months with OAS and the specific pacing algorithm (DAO) turned on, and three more months with the algorithm off. GROUP II: the inverse sequence to GROUP I. The pacing mode chosen was DDDR, and after three months patients underwent clinical and electronic evaluations of the stimulation system by: automatic mode switch (AMS), 24-hour Holter monitoring, Doppler echocardiogram, and SF-36 questionnaire. Following, a crossover comparison took place, and a new assessment was performed six months later. RESULTS: When compared to the group with the algorithm turned off, OAS patients had lower rates of: AF/week (p < 0.001); AMS activations (p < 0.01); hospitalizations (p < 0.001); cardioversions (p < 0.001), and higher scores on the physical and mental components of quality of life. CONCLUSION: The hybrid therapy adopted, OAS associated with the use of atenolol, reduced the rate of recurrent AF and improved the clinical-functional status of patients with symptomatic bradyarrhythmias.
Keywords