Scientific Reports (Jul 2022)
Comparison between two- and three-dimensional methods for offset measurements after total hip arthroplasty
Abstract
Abstract The aim of this study was to compare acetabular offset, femoral offset, and global offset measurements obtained after total hip arthroplasty (THA) between a two-dimensional (2D) method and a three-dimensional (3D) method. The subjects were 89 patients with unilateral osteoarthritis who underwent primary THA at our institution. Acetabular, femoral, and global offsets were measured by each of the 2D and 3D methods in native and implanted hips. In native hips, mean acetabular, femoral, and global offsets were 32.4 ± 3.3, 32.7 ± 4.5, 65.1 ± 5.7 mm, respectively, by the 2D method, and 32.3 ± 3.1, 38.1 ± 4.0, 70.4 ± 4.9 mm, respectively, by the 3D method. In implanted hips, mean acetabular, femoral, and global offsets were 27.6 ± 4.1, 33.8 ± 7.8, 61.4 ± 8.5 mm, respectively, by the 2D method, and 27.6 ± 3.9, 41.8 ± 6.2, 69.4 ± 7.2 mm, respectively, by the 3D method. There was significant difference in femoral and global offsets between the 2D and 3D methods in both native and implanted hips. Comparison of the 2D and 3D methods for evaluation of acetabular, femoral, and global offsets after THA clarified the usefulness and accuracy of the 3D method.