BMJ Open (Feb 2024)

Identifying neonates at risk for post-discharge mortality in Dar es Salaam, Tanzania, and Monrovia, Liberia: Derivation and internal validation of a novel risk assessment tool

  • Robert F Breiman,
  • Christopher R Sudfeld,
  • Rodrick Kisenge,
  • Christopher P Duggan,
  • Cynthia G Whitney,
  • Claudia R Morris,
  • Chris A Rees,
  • Readon C Ideh,
  • Michelle Niescierenko,
  • Karim P Manji,
  • Julia Kamara,
  • Abraham Samma,
  • Evance Godfrey,
  • Hussein K Manji,
  • Adrianna L Westbrook,
  • Ye-Jeung G Coleman-Nekar

DOI
https://doi.org/10.1136/bmjopen-2023-079389
Journal volume & issue
Vol. 14, no. 2

Abstract

Read online

Introduction The immediate period after hospital discharge carries a large burden of childhood mortality in sub-Saharan Africa. Our objective was to derive and internally validate a risk assessment tool to identify neonates discharged from the neonatal ward at risk for 60-day post-discharge mortality.Methods We conducted a prospective observational cohort study of neonates discharged from Muhimbili National Hospital in Dar es Salaam, Tanzania, and John F Kennedy Medical Centre in Monrovia, Liberia. Research staff called caregivers to ascertain vital status up to 60 days after discharge. We conducted multivariable logistic regression analyses with best subset selection to identify socioeconomic, demographic, clinical, and anthropometric factors associated with post-discharge mortality. We used adjusted log coefficients to assign points to each variable and internally validated our tool with bootstrap validation with 500 repetitions.Results There were 2344 neonates discharged and 2310 (98.5%) had post-discharge outcomes available. The median (IQR) age at discharge was 8 (4, 15) days; 1238 (53.6%) were male. In total, 71 (3.1%) died during follow-up (26.8% within 7 days of discharge). Leaving against medical advice (adjusted OR [aOR] 5.62, 95% CI 2.40 to 12.10) and diagnosis of meconium aspiration (aOR 6.98, 95% CI 1.69 to 21.70) conferred the greatest risk for post-discharge mortality. The risk assessment tool included nine variables (total possible score=63) and had an optimism corrected area under the receiver operating characteristic curve of 0.77 (95% CI 0.75 to 0.80). A score of ≥6 was most optimal (sensitivity 68.3% [95% CI 64.8% to 71.5%], specificity 72.1% [95% CI 71.5% to 72.7%]).Conclusions A small number of factors predicted all-cause, 60-day mortality after discharge from neonatal wards in Tanzania and Liberia. After external validation, this risk assessment tool may facilitate clinical decision making for eligibility for discharge and the direction of resources to follow-up high risk neonates.