International Journal of Electronics and Telecommunications (Feb 2021)

Measurement Capabilities Upgrade of GEM Soft X-ray Measurement System for Hot Plasma Diagnostics

  • Paweł Linczuk,
  • Andrzej Wojenski,
  • Piotr Kolasinski,
  • Rafał Krawczyk,
  • Wojciech Zabolotny,
  • Krzysztof Pozniak,
  • Maryna Chernyshova,
  • Tomasz Czarski,
  • Michał Gaska,
  • Grzegorz Kasprowicz,
  • Karol Malinowski

DOI
https://doi.org/10.24425/ijet.2021.135952
Journal volume & issue
Vol. vol. 67, no. No 1
pp. 115 – 120

Abstract

Read online

The paper presents improvements of the developed system for hot plasma radiation measurement in the soft Xray range based on a Gas Electron Multiplier (GEM) detector. Scope of work consists of a new solution for handling hardware time-synchronization with tokamak systems needed for better synchronization with other diagnostics and measurement quality. The paper describes the support of new modes of triggering on PC-side. There are communication and data path overview in the system. The new API is described, which provide separate channels for data and control and is more robust than the earlier solution. Work concentrates on stability and usability improvements of the implemented device providing better usage for end-user.

Keywords