Indian Journal of Ophthalmology (Jan 2014)
Evaluation of corneal biomechanical properties following penetrating keratoplasty using ocular response analyzer
- Vanathi Murugesan,
- Ravi Bypareddy,
- Mahesh Kumar,
- Dada Tanuj,
- Panda Anita
Affiliations
- Vanathi Murugesan
- Ravi Bypareddy
- Mahesh Kumar
- Dada Tanuj
- Panda Anita
- DOI
- https://doi.org/10.4103/0301-4738.119317
- Journal volume & issue
-
Vol. 62,
no. 4
pp. 454 – 460
Abstract
Purpose: To evaluate corneal biomechanical properties in eyes that has undergone penetrating keratoplasty (PK). Materials and Methods: Retrospective observational study in a tertiary care centre. Data recorded included ocular response analyzer (ORA) values of normal and post-keratoplasty eyes [corneal hysteresis (CH), corneal resistance factor (CRF), Goldmann-correlated intraocular pressure (IOPg), and cornea-compensated intraocular pressure (IOPcc)], corneal topography, and central corneal thickness (CCT). Wilcoxon signed rank test was used to analyze the difference in ORA parameter between post-PK eyes and normal eyes. Correlation between parameters was evaluated with Spearman′s rho correlation. Results: The ORA study of 100 eyes of 50 normal subjects and 54 post-keratoplasty eyes of 51 patients showed CH of 8.340 ± 1.85 and 9.923 ± 1.558, CRF of 8.846 ± 2.39 and 9.577 ± 1.631 in post-PK eyes and normal eyes, respectively. CH and CRF did not correlate with post-keratoplasty astigmatism (P = 0.311 and 0.276, respectively) while a significant correlation was observed with IOPg (P = 0.004) and IOPcc (P < 0.001). Conclusion: Biomechanical profiles were significantly decreased in post-keratoplasty eyes with significant correlation with higher IOP as compared with that in normal eyes.
Keywords
- Mean deviation
- non-proliferative diabetic retinopathy
- short fluctuations
- short wave automated perimetry
- standard automated perimetry
- Antimicrobial effect
- conventional silicone oil
- endophthalmitis agents
- heavy silicone oil
- Keratoconus
- modified deep anterior lamellar keratoplasty
- steep corneal curvature
- Bevacizumab
- branch retinal vein occlusion
- intravitreal
- macular edema
- triamcinolone
- Blindness
- disability evaluation
- quality of life
- visual acuity
- Mitomycin C
- pterygium recurrence
- pterygium surgery
- subconjunctival bevacizumab injection
- Imaging in glaucoma
- optical coherence tomography
- pediatric
- retinal nerve fiber layer
- Autogenous tissue grafting
- lacrimal drainage system
- lacrimal fossa
- bypass surgery
- Cornea
- excimer laser
- growth factors
- myopia
- photorefractive keratectomy
- Triamcinolone acetonide
- human trabecular meshwork cells
- in vitro
- Hyperopic implantable collamer lens
- myopic implantable collamer lens
- optical quality
- wavefront aberrations
- Dacryocystorhinostomy
- nasolacrimal duct obstruction
- silicone tube
- Age
- anterior chamber depth
- body height
- primary angle closure glaucoma
- sex
- Children
- eye injury vitrectomy study
- eye injury
- trauma
- vitrectomy
- Corneal biomechanics
- corneal hysteresis
- corneal resistance factor
- intraocular pressure
- keratoplasty
- ocular response analyser