Química Nova (Jan 2007)

Contaminação de aqüífero por hidrocarbonetos: estudo de caso na Vila Tupi, Porto Velho - Rondônia Hydrocarbon contamination in groundwater: the case of Tupi Village, Porto Velho-RO

  • Elcimar Juarez Forte,
  • Mariangela Soares Azevedo,
  • Ronaldo Cavalcante de Oliveira,
  • Ronaldo de Almeida

DOI
https://doi.org/10.1590/S0100-40422007000700008
Journal volume & issue
Vol. 30, no. 7
pp. 1539 – 1544

Abstract

Read online

Underground storage tanks (UST) are widely used in the Porto Velho area. A large number of these USTs are in bad condition due to corrosion processes causing groundwater contamination. A large number of these leaking underground fuel tanks (LUFT) are in urban areas but due to the lack of water quality monitoring, they are only detected when there is a high contamination level. This study identified petroleum hydrocarbons, derived from a LUFT, by a silica gel/petroleum ether partitioning gravimetric method and by gas chromatographic analysis of samples collected in wells dug in a gas station and in houses in the aforementioned neighborhood.

Keywords