Frontiers in Cardiovascular Medicine (Jul 2022)

Predictors of late arrhythmic events after generator replacement in Brugada syndrome treated with prophylactic ICD

  • Federico Migliore,
  • Nicolò Martini,
  • Leonardo Calo',
  • Annamaria Martino,
  • Giulia Winnicki,
  • Riccardo Vio,
  • Chiara Condello,
  • Alessandro Rizzo,
  • Alessandro Zorzi,
  • Luigi Pannone,
  • Vincenzo Miraglia,
  • Juan Sieira,
  • Gian-Battista Chierchia,
  • Antonio Curcio,
  • Giuseppe Allocca,
  • Roberto Mantovan,
  • Francesca Salghetti,
  • Antonio Curnis,
  • Emanuele Bertaglia,
  • Manuel De Lazzari,
  • Carlo de Asmundis,
  • Domenico Corrado

DOI
https://doi.org/10.3389/fcvm.2022.964694
Journal volume & issue
Vol. 9

Abstract

Read online

IntroductionPredictors of late life-threatening arrhythmic events in Brugada syndrome (BrS) patients who received a prophylactic ICD implantation remain to be evaluated. The aim of the present long-term multicenter study was to assess the incidence and clinical-electrocardiographic predictors of late life-threatening arrhythmic events in BrS patients with a prophylactic implantable cardioverter defibrillator (ICD) and undergoing generator replacement (GR).MethodsThe study population included 105 patients (75% males; mean age 45 ± 14years) who received a prophylactic ICD and had no arrhythmic event up to first GR.ResultsThe median period from first ICD implantation to last follow-up was 155 (128–181) months and from first ICD Implantation to the GR was 84 (61–102) months. During a median follow-up of 57 (38–102) months after GR, 10 patients (9%) received successful appropriate ICD intervention (1.6%/year). ICD interventions included shock on ventricular fibrillation (n = 8 patients), shock on ventricular tachycardia (n = 1 patient), and antitachycardia pacing on ventricular tachycardia (n = 1 patient). At survival analysis, history of atrial fibrillation (log-rank test; P = 0.02), conduction disturbances (log-rank test; P < 0.01), S wave in lead I (log-rank test; P = 0.01) and first-degree atrioventricular block (log-rank test; P = 0.04) were significantly associated with the occurrence of late appropriate ICD intervention. At Cox-regression multivariate analysis, S-wave in lead I was the only independent predictor of late appropriate ICD intervention (HR: 9.17; 95%CI: 1.15–73.07; P = 0.03).ConclusionsThe present study indicates that BrS patient receiving a prophylactic ICD may experience late appropriate intervention after GR in a clinically relevant proportion of cases. S-wave in lead I at the time of first clinical evaluation was the only independent predictor of persistent risk of life-threatening arrhythmic events. These findings support the need for GR at the end of service regardless of previous appropriate intervention, mostly in BrS patients with conduction abnormalities.

Keywords