EPJ Web of Conferences (Jan 2017)

Neutron transport calculation for Activation Evaluation for Decommissioning of PET cyclotron Facility

  • Nobuhara Fumiyoshi,
  • Kuroyanagi Makoto,
  • Masumoto Kazuyoshi,
  • Nakamura Hajime,
  • Toyoda Akihiro,
  • Takahashi Katsuhiko

DOI
https://doi.org/10.1051/epjconf/201715304007
Journal volume & issue
Vol. 153
p. 04007

Abstract

Read online

In order to evaluate the state of activation in a cyclotron facility used for the radioisotope production of PET diagnostics, we measured the neutron flux by using gold foils and TLDs. Then, the spatial distribution of neutrons and induced activity inside the cyclotron vault were simulated with the Monte Calro calculation code for neutron transport and DCHAIN-SP for activation calculation. The calculated results are in good agreement with measured values within factor 3. Therefore, the adaption of the advanced evaluation procedure for activation level is proved to be important for the planning of decommissioning of these facilities.