Diagnostics (Apr 2023)
Clinical Validation of a Colorimetric Loop-Mediated Isothermal Amplification Using a Portable Device for the Rapid Detection of SARS-CoV-2
Abstract
Quick and reliable mass testing of infected people is an effective tool for the contingency of SARS-CoV-2. During the COVID-19 pandemic, Point-of-Care (POC) tests using Loop-Mediated Isothermal Amplification (LAMP) arose as a useful diagnostic tool. LAMP tests are a robust and fast alternative to Polymerase Chain Reaction (PCR), and their isothermal property allows easy incorporation into POC platforms. The main drawback of using colorimetric LAMP is the reported short-term stability of the pre-mixed reagents, as well as the relatively high rate of false-positive results. Also, low-magnitude amplification can produce a subtle color change, making it difficult to discern a positive reaction. This paper presents Hilab Molecular, a portable device that uses the Internet of Things and Artificial Intelligence to pre-analyze colorimetric data. In addition, we established manufacturing procedures to increase the stability of colorimetric RT-LAMP tests. We show that ready-to-use reactions can be stored for up to 120 days at −20 °C. Furthermore, we validated both the Hilab Molecular device and the Hilab RT-LAMP test for SARS-CoV-2 using 581 patient samples without any purification steps. We achieved a sensitivity of 92.93% and specificity of 99.42% (samples with CT ≤ 30) when compared to RT-qPCR.