One-Piece Zirconia Oral Implants for the Support of Three-Unit Fixed Dental Prostheses: Three-Year Results from a Prospective Case Series

  • Ralf-Joachim Kohal,
  • Kirstin Vach,
  • Frank Butz,
  • Benedikt Christopher Spies,
  • Sebastian Berthold Maximilian Patzelt,
  • Felix Burkhardt

DOI
https://doi.org/10.3390/jfb14010045
Journal volume & issue
Vol. 14, no. 1
p. 45

Abstract

Read online

The objective was to investigate the clinical and radiological outcome of one-piece zirconia oral implants to support three-unit fixed dental prostheses (FDP) after three years in function. Twenty-seven patients were treated with a total of 54 implants in a one-stage surgery and immediate provisionalization. Standardized radiographs were taken at implant placement, after one year and after three years, to evaluate peri-implant bone loss. Soft-tissue parameters were also assessed. Linear mixed regression models as well as Wilcoxon Signed Rank tests were used for analyzing differences between groups and time points (p < 0.05). At the three-year evaluation, one implant was lost, resulting in a cumulative survival rate of 98.1%. The mean marginal bone loss amounted to 2.16 mm. An implant success grade I of 52% (bone loss of ≤2 mm) and success grade II of 61% (bone loss of ≤3 mm) were achieved. None of the evaluated baseline parameters affected bone loss. The survival rate of the zirconia implants was comparable to market-available titanium implants. However, an increased marginal bone loss was observed with a high peri-implantitis incidence and a resulting low implant success rate.