PLoS ONE (Jan 2019)

Lower plasma insulin levels during overnight closed-loop in school children with type 1 diabetes: Potential advantage? A randomized cross-over trial.

  • Ulrike Schierloh,
  • Malgorzata E Wilinska,
  • Ineke M Pit-Ten Cate,
  • Petra Baumann,
  • Roman Hovorka,
  • Carine De Beaufort,
  • Spidiman Study Group: Single Port Insulin Infusion for Improved Diabetes Management

DOI
https://doi.org/10.1371/journal.pone.0212013
Journal volume & issue
Vol. 14, no. 3
p. e0212013

Abstract

Read online

BackgroundStudies have shown that overnight closed-loop insulin delivery can improve glucose control and reduce the risk of hypoglycemia and hence may improve metabolic outcomes and reduce burden for children with type 1 diabetes and their families. However, research so far has not reported insulin levels while comparing closed-loop to open-loop insulin delivery in children. Therefore, in this study we obtained glucose levels as well as plasma insulin levels in children with type 1 diabetes to evaluate the efficacy of a model-based closed-loop algorithm compared to an open-loop administration.MethodsFifteen children with type 1 diabetes, 6-12 years, participated in this open-label single center study. We used a randomized cross over design in which we compared overnight closed-loop insulin delivery with sensor augmented pump therapy for two nights in both the hospital and at home (i.e., 1 night in-patient stay and at home per treatment condition). Only during the in-patient stay, hourly plasma insulin and blood glucose levels were assessed and are reported in this paper.ResultsResults of paired sample t-tests revealed that although plasma insulin levels were significantly lower during the closed-loop than in the open-loop (Mean difference 36.51 pmol/l; t(13) = 2.13, p = .03, effect size d = 0.57), blood glucose levels did not vary between conditions (mean difference 0.76 mmol/l; t(13) = 1.24, p = .12, d = 0.37). The administered dose of insulin was significantly lower during the closed-loop compared with the open-loop (mean difference 0.10 UI; t(12) = 2.45, p = .02, d = 0.68).ConclusionsLower insulin doses were delivered in the closed-loop, resulting in lower plasma insulin levels, whereby glucose levels were not affected negatively. This suggests that the closed-loop administration is better targeted and hence could be more effective.