Journal of International Medical Research (Feb 2020)

Finite element analysis of a new plate for Pauwels type III femoral neck fractures

  • Gang Wang,
  • Yong Tang,
  • Xuhua Wu,
  • Huilin Yang

DOI
https://doi.org/10.1177/0300060520903669
Journal volume & issue
Vol. 48

Abstract

Read online

Background A new plate for the treatment of Pauwels type III femoral neck fractures was developed, and its biomechanical stability was analyzed by the finite element method. Method Using 3-matic and UG-NX software, we constructed models of Pauwels type III femoral neck fractures with angles of 50°, 60°, and 70°. Moreover, a new femoral neck plate (NFNP) fixation model and a Pauwels screw fixation model were developed. Under axial loads of 1400 N and 2100 N, von Mises stress (VMS) distribution on the screws, peak VMS, displacement between fracture fragments, and model principal strains in cancellous bone were recorded. Result The peak VMS of internal fixation in the two models was mostly located near the fracture line, and the screw closest to the femoral calcar experienced maximum stress. With a Pauwels angle of 50°, 60°, and 70°, the peak VMS values of the new plates were lower than in the Pauwels screw. The displacement of fracture fragments in the NFNP was smaller than in the Pauwels screw, and peak VMS values of cancellous bone in the NFNP were lower than in the Pauwels screw. Conclusion The newly developed plate provided excellent biomechanical stability for Pauwels type III femoral neck fractures.