IET Power Electronics (Nov 2023)

Modified indirect rotor field‐oriented control strategies for wye‐connected three‐phase induction motor drives under an open‐phase fault

  • Bahman Yousefi,
  • Mahmood Ghanbari,
  • Reza Ebrahimi,
  • Mohammad Jannati

DOI
https://doi.org/10.1049/pel2.12558
Journal volume & issue
Vol. 16, no. 14
pp. 2378 – 2391

Abstract

Read online

Abstract Field‐oriented control (FOC) has been broadly used as an accurate control method for electric drives. The traditional FOC approach has been effectively developed to 3‐phase induction motor (3φ IM) drive systems in recent decades. Despite the usefulness of FOC methods during normal condition, these strategies are unable to control a wye‐connected 3φ IM (3φ IMy) under the stator winding open circuit fault (SWOCF). This paper discusses modified indirect rotor FOC (FOCIR) strategies for 3φ IMy drives under the SWOCF. The αβ stationary reference frame (RF) model is presented and utilized to develop vector control systems for the faulty 3φ IMy using asymmetrical transformations. This model is also used to propose a modified FOCIR method for 3φ IMy drives against the SWOCF based on the symmetrical/traditional transformation and using the bi‐voltage controller. The performances of the presented control methods are confirmed via simulations and experiments for a 3φ IMy considering the SWOCF. The achieved results show the effectiveness of modified FOCIR strategies for vector control of the faulty 3φ IMy drive.

Keywords