Development and Validation of a Simple and Sensitive LC-MS/MS Method for Quantification of Metformin in Dried Blood Spot Its Application as an Indicator for Medication Adherence

  • ALquadeib BT,
  • Aloudah NM,
  • Almurshedi AS,
  • ALfagih IM,
  • ALdosari BN,
  • ALmeleky AS,
  • Almubyedh NM

Journal volume & issue
Vol. Volume 14
pp. 3225 – 3233

Abstract

Read online

Bushra T ALquadeib,1,* Nouf M Aloudah,2,* Alanood S Almurshedi,1 Iman M ALfagih,1 Basmah N ALdosari,1 Adim S ALmeleky,3 Nour M Almubyedh3 1Department of Pharmaceutics, College of Pharmacy, King Saud University, Riyadh, 11671, Saudi Arabia; 2Department of Clinical Pharmacy, College of Pharmacy, King Saud University, Riyadh, 11671, Saudi Arabia; 3College of Pharmacy, King Saud University, Riyadh, 11671, Saudi Arabia*These authors contributed equally to this workCorrespondence: Bushra T ALquadeib Email [email protected]: Metformin (MET), an oral biguanide agent, can improve insulin resistance and decrease hepatic glucose production, leading to a reduction in blood-sugar levels. The objective of the present study was to develop and validate simple and rapid LC-MS/MS method for analysis of MET in dried blood spot (DBS) sample for patient monitoring studies purposes (drug adherence).Methods: The chromatographic separation was achieved with Waters HSS-T3 column using gradient elution of mobile phases of two solvents: 1) solvent A, consisted of 10mM ammonium formate, 0.2% formic acid 1%; and 2) acetonitrile solvent B, contained 0.2% formic acid in acetonitrile at a flow rate of 0.2 mL/min. The total run time was 3.0 min. The effectiveness of chromatographic conditions was optimized, and afatinib was used as the internal standard. The assay method was validated using USP 26 and the ICH guidelines.Results: The method showed good linearity in the range 8– 48 ng/mL for MET with correlation coefficient (r) > 0.9907. The intra- and inter‑day precision values for MET met the acceptance criteria as per regulatory guidelines. MET was stable during the stability studies at ambient temperature 25 °C, at refrigerator 4 °C, at 10 °C autosampler, freeze/thaw cycles and 30 days storage in a freezer at − 30 ± 0.5 °C.Conclusion: This method has successfully fulfilled all validation requirements referring to EMA and FDA guidelines, and successfully can be applied for MET adherence study. All the six studied patients were approved to metformin adherence.Keywords: metformin, dried blood spot, liquid chromatography–tandem mass spectrometry, method validation, medication adherence

Keywords