Известия высших учебных заведений: Проблемы энергетики (Dec 2017)

Filtering the phase voltages of the frequency converter in the identification of the parameters of three-phase asynchronous motor

  • A. J. Afanasiev,
  • V. G. Makarov,
  • Y. A. Yakovlev,
  • V. N. Khannanova

DOI
https://doi.org/10.30724/1998-9903-2015-0-9-10-52-62
Journal volume & issue
Vol. 0, no. 9-10
pp. 52 – 62

Abstract

Read online

The expediency of application of active filters Butterworth third order to highlight the basic harmonic of the phase voltages of a two-level frequency converter in the identification of the parameters of three-phase asynchronous motor is shown. For the implementation of the identification algorithm it is necessary to convert the output voltages of the filters in the voltage phases of the stator winding of the generalized electric machine. It is experimentally determined that the presence offilters low frequency does not introduce significant distortion and allows to obtain the necessary shape of the phase voltages of the generalized electric machine.

Keywords