Emerging Microbes and Infections (Jan 2020)
Delayed specific IgM antibody responses observed among COVID-19 patients with severe progression
Abstract
ABSTRACTSevere acute respiratory syndrome coronavirus 2 (SARS-CoV-2) has spread rapidly worldwide since it was confirmed as the causative agent of COVID-19. Molecular diagnosis of the disease is typically performed via nucleic acid-based detection of the virus from swabs, sputum or bronchoalveolar lavage fluid (BALF). However, the positive rate from the commonly used specimens (swabs or sputum) was less than 75%. Immunological assays for SARS-CoV-2 are needed to accurately diagnose COVID-19. Sera were collected from patients or healthy people in a local hospital in Xiangyang, Hubei Province, China. The SARS-CoV-2 specific IgM antibodies were then detected using a SARS-CoV-2 IgM colloidal gold immunochromatographic assay (GICA). Results were analysed in combination with sera collection date and clinical information. The GICA was found to be positive with the detected 82.2% (37/45) of RT-qPCR confirmed COVID-19 cases, as well as 32.0% (8/25) of clinically confirmed, RT-qPCR negative patients (4–14 days after symptom onset). Investigation of IgM-negative, RT-qPCR-positive COVID-19 patients showed that half of them developed severe disease. The GICA was found to be a useful test to complement existing PCR-based assays for confirmation of COVID-19, and a delayed specific IgM antibody response was observed among COVID-19 patients with severe progression.
Keywords