Buildings (Dec 2023)

Bond Strength of Reinforcing Steel Bars in Self-Consolidating Concrete

  • Micheal Asaad,
  • George Morcous

DOI
https://doi.org/10.3390/buildings13123009
Journal volume & issue
Vol. 13, no. 12
p. 3009

Abstract

Read online

This paper presents an experimental investigation of the bond strength of reinforcing steel bars in tension in self-consolidating concrete (SCC). The effects of the reinforcing bar’s location, orientation, size, and coating on the bond strength with SCC were studied and compared to those with conventionally vibrated concrete (CVC). Several SCC mixtures were developed to cover a wide range of applications/components and material types. The fresh properties of the SCC mixtures were determined to evaluate their filling ability, passing ability and stability. Two hundred and thirty-four pull-out tests of rebars embedded in cubes, wall panels and slabs were conducted. Almost half of the tests were conducted to evaluate the bond with SCC and the other half with CVC. Load–slippage relationships were measured for each test. Pull-out test results were analyzed, and the bond strength was reported in two values: critical strength, which corresponds to slippage of 0.01 in. *0.25 mm); and ultimate strength, which corresponds to the maximum load. The critical strength of SCC and CVC were compared against the ACI 318-19 provisions and comparisons between the ultimate strength of SCC and CVC were conducted. The comparisons indicated that SCC has lower bond strength with vertical rebars than CVC, and a 1.3 development length modification factor is recommended. A similar conclusion applies to epoxy-coated and large diameter rebars. Also, SCC with high slump flow has shown a less top-bar effect than that of CVC.

Keywords