Augmented Reality‐Guided Frozen Section Analysis: Bringing the Pathologist From the Laboratory to the Operating Room
Abstract
Abstract Due to the anatomic complexity of the head and neck and variable proximity between laboratory and operating room (OR), effective communication during frozen section analysis (FSA) between surgeons and pathologists is challenging. This proof‐of‐concept study investigates an augmented reality (AR) protocol that allows pathologists to virtually join the OR from the laboratory. Head and neck cancer specimens were scanned ex vivo using a 3‐dimensional scanner and uploaded into an AR platform. Eight head and neck specimens were discussed by surgeons and pathologists in an AR environment. AR‐guided intraoperative consultation was used for specimen orientation and discussion of FSA margin sampling sites. One patient had positive initial margins on FSA and was re‐resected to negative final margins. AR‐guided FSA is possible and allows pathologists to join the operating from any location for intraoperative discussion.