Nuclear Engineering and Technology (Aug 2022)

Study on failure mechanism of line contact structures of nuclear graphite

  • Shigang Jia,
  • Yanan Yi,
  • Lu Wang,
  • Guangyan Liu,
  • Qinwei Ma,
  • Libin Sun,
  • Li Shi,
  • Shaopeng Ma

Journal volume & issue
Vol. 54, no. 8
pp. 2989 – 2998

Abstract

Read online

Line contact structures, such as the contact between graphite brick and graphite tenon, widely exist in high-temperature gas-cooled reactors. Due to the stress concentration effect, the line contact area is one of the dangerous positions prone to failure in the nuclear reactor core. In this paper, the failure mechanism of line contact structures composed of IG11 nuclear graphite column and brick were investigated by means of experiment and finite element simulation. It was found that the failure process mainly includes three stages: firstly, the damage accumulation in nuclear graphite material led to the characteristic yielding of the line contact structure, but no macroscopic failure can be observed at this stage; secondly, the stresses near the contact area met Mohr failure criterion, and a crack initiated and propagated laterally in the contact zone, that is, local macroscopic failure occurred at this stage; finally, a second crack initiated in the contact area and developed in to a Y-shape, resulting in the final failure of the structure. This study lays a foundation for the structural design and safety assessment of high-temperature gas-cooled reactors.

Keywords