Civil and Environmental Engineering (Dec 2018)

Determination of Pressure Coefficient for a High-Rise Building with Atypical Ground Plan

  • Medvecká Soňa,
  • Ivánková Ol’ga,
  • Macák Marek,
  • Michalcová Vladimíra

DOI
https://doi.org/10.2478/cee-2018-0018
Journal volume & issue
Vol. 14, no. 2
pp. 138 – 145

Abstract

Read online

In this article, the results of pressure coefficient on the atypical object obtained by experimental measurements in a boundary layer wind tunnel (BLWT) of Slovak University of Technology in Bratislava (STU) and computational fluid dynamics simulation (CFD) are presented. The pressure coefficient is one of the most important parameters expressing the wind pressure distribution on the structure. The loading by wind can only be acquired by execution of detailed tests and numerical analyses [1].

Keywords