Sensors (Jul 2021)

Molecular Monolayer Sensing Using Surface Plasmon Resonance and Angular Goos-Hänchen Shift

  • Cherrie May Olaya,
  • Norihiko Hayazawa,
  • Maria Vanessa Balois-Oguchi,
  • Nathaniel Hermosa,
  • Takuo Tanaka

DOI
https://doi.org/10.3390/s21134593
Journal volume & issue
Vol. 21, no. 13
p. 4593

Abstract

Read online

We demonstrate potential molecular monolayer detection using measurements of surface plasmon resonance (SPR) and angular Goos-Hänchen (GH) shift. Here, the molecular monolayer of interest is a benzenethiol self-assembled monolayer (BT-SAM) adsorbed on a gold (Au) substrate. Excitation of surface plasmons enhanced the GH shift which was dominated by angular GH shift because we focused the incident beam to a small beam waist making spatial GH shift negligible. For measurements in ambient, the presence of BT-SAM on a Au substrate induces hydrophobicity which decreases the likelihood of contamination on the surface allowing for molecular monolayer sensing. This is in contrast to the hydrophilic nature of a clean Au surface that is highly susceptible to contamination. Since our measurements were made in ambient, larger SPR angle than the expected value was measured due to the contamination in the Au substrate. In contrast, the SPR angle was smaller when BT-SAM coated the Au substrate due to the minimization of contaminants brought about by Au surface modification. Detection of the molecular monolayer acounts for the small change in the SPR angle from the expected value.

Keywords