VideoGIE (Jan 2020)
EUS-guided stent removal in buried lumen-apposing metal stent syndrome: a case series
Abstract
Background and Aims: Lumen-apposing metal stents (LAMSs) play an increasing role in transgastric and transduodenal drainage of pancreatic fluid collections and allow novel EUS-guided interventions. Alongside the main adverse events of bleeding and occlusion, LAMSs can be overgrown by mucosa, which leads to the inability to visualize the stent in endoscopy. Methods: We describe a series of 4 cases of buried LAMSs that were removed under EUS guidance for identification of the stent followed by removal with rat-tooth forceps. Results: The median in situ time of the LAMSs in the reported 4 cases was 53 days. All stents could no longer be visualized endoscopically when drainage of necrosis was complete. All 4 buried LAMSs could be identified by EUS and were removed successfully with forceps. In 1 case, balloon dilation of the stent tract was performed before stent removal. No adverse events were observed after the procedure. Conclusions: Buried stent syndrome is a rare adverse event of LAMSs. Here we describe a safe and effective approach for stent identification and removal without prior mucosal dissection.