AIP Advances (Apr 2022)

Microwave breakdown of sub-atmospheric argon gas in the vicinity of a microgap

  • M. E. Castelan Hernandez,
  • S. M. Woodwyk,
  • W. G. Zywicki,
  • Z. T. Kellner,
  • A. R. Medema,
  • G. T. Lenters,
  • S. K. Remillard

DOI
https://doi.org/10.1063/5.0082854
Journal volume & issue
Vol. 12, no. 4
pp. 045001 – 045001-6

Abstract

Read online

The microwave electric field at breakdown for argon gas in a microgap (generally, gap size <1 mm) over a wide range of pressures and gap sizes was found to exhibit two behavioral pressure regimes. A high microwave electric field was established in the gap of a re-entrant mode resonator. By slowly raising the microwave electric field level, a breakdown level is reached where impact ionization induces low pressure argon gas to breakdown preferentially outside of the gap. At high pressure, breakdown is found to occur preferentially inside the gap, but only after the pressure is high enough for impact ionization to produce breakdown there. Impact ionization has a lower threshold electric field than the boundary-controlled processes, such as secondary electron emission, that would eventually produce breakdown inside the microgap if impact ionization did not occur first. Thus, the lower pressure regime is characterized by breakdown outside of the gap, while in the high-pressure regime, breakdown occurs inside the gap, in both cases by impact ionization. The transition pressure PT between these two pressure regimes depends on the gap size dgap, roughly as PT ∝ dgap−2. Consistent with the model developed here, this corresponds to the full-amplitude of electron oscillation in the gap field being commensurate with the gap size.