Journal of Ophthalmology (Jan 2021)
A Comparative Study of Two Types of Implantation Surgery Methods for Implantable Collamer Lenses
Abstract
Purpose. To investigate the effects of two different surgical methods of implantable collamer lens (ICL) implantation on the operation time, visual outcomes, corneal endothelial cell count, and intraocular pressure (IOP). Methods. This was a contralateral eye comparison study, a total of 192 eyes from 96 patients were included, and the two eyes from the same patient were randomly assigned to two groups (group 1 and group 2, with 96 eyes in each group). In group 1, after making the corneal incision, ophthalmic viscosurgical devices (OVDs) were first injected into the anterior chamber followed by ICL implantation. In group 2, the ICL was first implanted into the anterior chamber followed by OVDs injection. The operation time, uncorrected distance visual acuity, corrected distance visual acuity, spherical equivalent, corneal endothelial cell count, and IOP were recorded and analyzed. Results. The operative time in group 1 was significantly longer than that in group 2 (P = 0.002 0.05). Conclusion. The two ICL implantation methods had similar clinical outcomes and effects on the corneal endothelial cell count. Additionally, the implantation of an intraocular lens prior to injecting OVDs reduces the operation time and lowers the rate of IOP rise in the early postoperative period, making it safe and effective for ICL implantation.