Experimental and Parametric Analysis of Pull-Out Resistance of Notched T-Perfobond Connectors

  • Zifa Dong,
  • Shuangjie Zheng,
  • Lizhe Jiao,
  • Xiaoqing Xu,
  • Yao Yao,
  • Zhuoru Gao,
  • Haifeng Li

DOI
https://doi.org/10.3390/app14167089
Journal volume & issue
Vol. 14, no. 16
p. 7089

Abstract

Read online

To enhance the uplift capacity and facilitate the installation of multi-row perfobond connectors at shallow burial depths, this study puts forward a novel notched T-perfobond connector. The design incorporates an integrated flange at the bottom of the connector and a notch at the edge of the hole. Through pull-out model tests on four notched T-perfobond connectors, this research investigates their failure mechanisms and pull-out capacities. Utilizing the explicit dynamics method in ABAQUS, a finite-element model of the pull-out resistance test for notched T-perfobond connectors is established and verified against experimental data. Furthermore, a detailed parametric analysis involving 54 models is conducted, examining crucial parameters such as rib dimensions, hole geometry, flange size, notch width, bar diameter, and material properties. Based on the combined experimental and numerical results, this paper assesses the suitability of current formulas for calculating the pull-out capacity of perfobond connectors and proposes a refined calculation method specifically for notched T-perfobond connectors. All the findings reported in this paper can serve as a reference in the design and construction of composite structures.

Keywords