Clinical Ophthalmology (Nov 2021)

Comparison of 3D Digitally Assisted Visualization System with Current Standard Visualization for the Removal of Vitreous in a Preclinical Model

  • Mura M,
  • Martin W,
  • Williams KK,
  • Abulon DJK

Journal volume & issue
Vol. Volume 15
pp. 4499 – 4505

Abstract

Read online

Marco Mura,1– 3 Wendy Martin,4 K Keven Williams,4 Dina Joy K Abulon5 1Department of Translational Medicine, University of Ferrara, Ferrara, Italy; 2Department of Ophthalmology, University of Illinois, Chicago, IL, USA; 3Vitreoretinal Division, King Khaled Eye Specialist Hospital, Riyadh, Saudi Arabia; 4Preclinical Development, Alcon Vision LLC, Fort Worth, TX, USA; 5Global Medical Affairs, Alcon Vision LLC, Irvine, CA, USACorrespondence: Marco MuraDepartment of Translational Medicine, University of Ferrara, Via Luigi Borsari 46, Ferrara, 44121, ItalyTel +390532455845Fax +390532207351Email [email protected]: Novel 3D digital display systems, such as NGENUITY 3D digitally assisted visualization system (DAVS), can provide enhanced illumination, depth of field, and digital filtering. This study compared vitreous removal using NGENUITY 3D DAVS with a standard surgical microscope.Methods: This was an in vivo, 2-arm laboratory study in 15 Yorkshire pig eyes. The LuxOR LX3 microscope with NGENUITY 3D DAVS (arm 1) and the LuxOR LX3 microscope alone (arm 2) were used with 5× optical magnification and Oculus BIOM 200 mm optics. Standard core and peripheral vitrectomy without scleral depression was performed using the CONSTELLATION Vision System. Residual vitreous weight was assessed in enucleated eyes by a masked observer. Axial length and vitreous weight of contralateral eyes were compared from an additional 14 Yorkshire pigs to confirm that eyes from a single animal were essentially identical.Results: After vitrectomy, mean ± SD residual vitreous was significantly smaller with NGENUITY versus standard microscope (0.143 ± 0.146 versus 0.580 ± 0.269 g, respectively; P < 0.0001). Based on a mean initial vitreous weight of 2.5 g, as determined by assessment in contralateral eyes from an additional 14 Yorkshire pigs, the mean percentage vitreous removal was 94% ± 6% versus 77% ± 11%, respectively. Further, vitreous weight and axial length for contralateral eyes from any single animal in these additional 14 animals were essentially identical, as mean differences were 0.046 ± 0.035 g and 0.11 ± 0.08 mm, respectively.Conclusion: Vitrectomy with NGENUITY 3D DAVS resulted in significantly less residual vitreous in pig eyes compared with standard microscopy. NGENUITY may improve vitreous removal during vitreoretinal surgery by enhancing visualization.Keywords: 3D digital display systems, NGENUITY, vitrectomy

Keywords