IET Electric Power Applications (Oct 2024)
Derating factor determination of the three‐phase induction motor under unbalanced voltage using pumping system
Abstract
Abstract A novel method is presented for determining the derating factors of a three‐phase induction motor under the condition of the unbalanced supply voltages. In this method, a mechanical system is used which consist of the a centrifugal pump, two valves, a DC motor, which are connected to the shaft of the three‐phase induction motor. A sliding mode control system is used for position control of the DC motor for adjusting the valve angle for derating the induction motor. The authors present the results of an experiment in which a three‐phase induction motor was subjected to various unbalanced voltage conditions. The results of simulations were used to look into what happened when there were different levels of imbalanced voltage. This was done to determine how these situations changed an induction motor's speed, torque, and efficiency. For this system, the stator current would be greater than the rated current if there was an imbalance in the supply voltage. Therefore, to reduce the amount of power that the three‐phase induction motor can produce, the control system uses a DC motor to reduce the angle of one of the two valves. This decreasing angle continues until the root mean square value of the stator current returns to the rated current. At this point, the derating factor may be calculated by dividing the output power of the three‐phase induction motor in the unbalanced condition by the output power when there are ideal sinusoidal. The MATLAB SIMULINK environment is utilised to perform simulations of the proposed system.
Keywords