Cancers (Apr 2022)

Sulfur Exafluoride Contrast-Enhanced Ultrasound Showing Early Wash-Out of Marked Degree Identifies Lymphoma Invasion of Spleen with Excellent Diagnostic Accuracy: A Monocentric Study of 260 Splenic Nodules

  • Marco Picardi,
  • Claudia Giordano,
  • Fabio Trastulli,
  • Aldo Leone,
  • Roberta Della Pepa,
  • Novella Pugliese,
  • Rossella Iula,
  • Giuseppe Delle Cave,
  • Maria Gabriella Rascato,
  • Maria Esposito,
  • Elena Vigliar,
  • Giancarlo Troncone,
  • Massimo Mascolo,
  • Daniela Russo,
  • Marcello Persico,
  • Fabrizio Pane

DOI
https://doi.org/10.3390/cancers14081927
Journal volume & issue
Vol. 14, no. 8
p. 1927

Abstract

Read online

Contrast-enhanced ultrasonography (CEUS) use for detecting lymphoma in the spleen was questioned because of the risk of its inadequate diagnostic accuracy. The aim of the present study was to validate CEUS exam for the identification of spleen involvement by lymphoma in patients at risk. A total of 260 nodules from the spleens of 77 patients with lymph node biopsy-proven non-Hodgkin lymphoma (NHL; n = 44) or Hodgkin lymphoma (HL; n = 33) at staging (n = 56) or follow-up (n = 21) were collected in a hematology Italian center and retrospectively analyzed. Nodules were classified as malignant lymphoma if ≥0.5 cm (long axis) with arterial phase isoen-hancement and early (onset <60 s after contrast agent injection) wash-out of marked (≤120 s after contrast agent injection) degree. Other perfusional combinations at CEUS scans qualified lesions as benign or inconclusive. Diagnostic reference standard was clinical laboratory imaging monitoring for 230 nodules, and/or histology for 30 nodules. The median nodule size was 1.5 cm (range 0.5–7 cm). According to the reference standard, 204 (78%) nodules were lymphomas (aggressive-NHL (a-NHL), 122; classic-HL (c-HL), 65; indolent (i)-NHL, 17) and 56 (22%) were benign (inflammation, infection, and/or mesenchymal) lesions. Sensitivity, specificity, positive predictive value, negative predictive value, and overall diagnostic accuracy of CEUS for detecting lymphoma in the spleen were 95%, 100%, 100%, 85%, and 96%, respectively. Marked wash-out range of 55–90 s (median, 74 s), 92–120 s (median, 100 s), and 101–120 s (median, 114.5 s) was 100%, 96.6%, and 77% predictive of a-NHL, c-HL, and i-NHL splenic nodular infiltration, respectively. The CEUS perfusional pattern of arterial phase isoenhancement with early wash-out of marked degree was highly accurate for the detection of lymphomatous invasion of spleen in patients at risk, enabling its use for a confident non-invasive diagnosis.

Keywords