Materials Research Express (Jan 2019)

Asymmetrical compound parabolic concentrator with single flow system: field-test scale, thermal performance parameters, and E. coli inactivation

  • Wreerat Laithong,
  • Phattarathicha Tepsri,
  • Sirichai Thepa,
  • Roongrojana Songprakorp,
  • Sorachon Yoriya

DOI
https://doi.org/10.1088/2053-1591/ab34d7
Journal volume & issue
Vol. 6, no. 10
p. 105501

Abstract

Read online

This work presents a developed field-test scaled asymmetrical compound parabolic concentrator (ACPC) and an investigation of its performance with a single flow system of water on Escherichia coli inactivation. As a function of water flow rate, ability to produce hot water of the ACPC and hence inhibit the growth of bacterial in water is focused to study; the flow rates varied are 0.2, 0.4, and 0.6 l min ^−1 . With a design and choice of material, the constructed ACPC unit with 0.2 l min ^−1 could produce hot water with maximum temperature of 76.4 °C, with lower flow rates resulting in the lower outlet water temperature and consequently the reduced kinetics of bacteria inactivation. Thermal performance parameters have been described in a correlative view with the particular operation condition and flow rate variables through mathematic calculation. The effect of inlet driving temperature, believed to play a significant role controlling the outlet temperature, on E. coli inactivation has been investigated.

Keywords