AIP Advances (Aug 2022)

Research on the traceability method based on half symmetric superposition

  • Jin Bao,
  • Meimei Duan,
  • Jun Li

DOI
https://doi.org/10.1063/5.0102728
Journal volume & issue
Vol. 12, no. 8
pp. 085106 – 085106-8

Abstract

Read online

In order to achieve high-accuracy self-calibration and traceability of electromagnetic standard voltage transformers, a measurement method that can be used for voltage ratio standard error voltage coefficients is proposed. Using two auxiliary standard voltage transformers, the error variation of the voltage transformer under different voltages can be obtained through three-step measurement. Compared with the traditional error voltage coefficient measurement method and international comparison, the feasibility of the method and the rationality of the uncertainty evaluation of the measurement results are verified. The self-calibration ratio difference measurement uncertainty of the 110 kV standard voltage transformer is better than 5 × 10−6, and the angular difference measurement uncertainty is better than 5 µrad. The method can be used to trace the source of standard devices up to 1000 kV power frequency voltage ratio, which have characteristics such as high accuracy and good stability.