Frontiers in Pediatrics (Apr 2023)

A novel image integration technology mapping system significantly reduces radiation exposure during ablation for a wide spectrum of tachyarrhythmias in children

  • Jiang He,
  • Zhang Yi,
  • Li Meiting,
  • Zhou Huiming,
  • Li Jinhao,
  • Chen Danlei,
  • Li Xiaomei

DOI
https://doi.org/10.3389/fped.2023.1148745
Journal volume & issue
Vol. 11

Abstract

Read online

ObjectiveRadiofrequency catheter ablation (RFCA) has evolved into an effective and safe technique for the treatment of tachyarrhythmia in children. Concerns about children and involved medical staff being exposed to radiation during the procedure should not be ignored. “Fluoroscopy integrated 3D mapping”, a new 3D non-fluoroscopic navigation system software (CARTO Univu Module) could reduce fluoroscopy during the procedure. However, there are few studies about the use of this new technology on children. In the present study, we analyzed the impact of the CARTO Univu on procedural safety and fluoroscopy in a wide spectrum of tachyarrhythmias as compared with CARTO3 alone.MethodsThe data of children with tachyarrhythmias who underwent RFCA from June 2018 to December 2021 were collected. The CARTO Univu was used for mapping and ablation in 200 cases (C3U group) [boys/girls (105/95), mean age (6.8 ± 3.7 years), mean body weight (29.4 ± 7.9 kg)], and the CARTO3 was used in 200 cases as the control group (C3 group) [male/female (103/97), mean age (7.2 ± 3.9 years), mean body weight (32.3 ± 19.0 kg)]. The arrhythmias were atrioventricular reentrant tachycardia (AVRT, n = 78), atrioventricular node reentrant tachycardia (AVNRT, n = 35), typical atrial flutter (AFL, n = 12), atrial tachycardia (AT, n = 20) and ventricular arrhythmias [VAs, premature ventricular complexes or ventricular tachycardia, n = 55].Results① There was no significant difference in the acute success rate, recurrence rate, and complication rate between the C3 and C3U groups [(94.5% vs. 95.0%); (6.3% vs. 5.3%); and (2.0% vs. 1.5%); P > 0.05]. ② The CARTO Univu reduced radiation exposure: fluoroscopy time: AVRT C3: 8.5 ± 7.2 min vs. C3U: 4.5 ± 2.9 min, P < 0.05; AVNRT C3: 10.7 ± 3.2 min vs. C3U: 4.3 ± 2.6 min, P < 0.05; AT C3: 15.7 ± 8.2 min vs. C3U: 4.5 ± 1.7 min, P < 0.05; AFL C3: 8.7 ± 3.2 min vs. C3U: 3.7 ± 2.7 min, P < 0.05; VAs C3: 7.7 ± 4.2 min vs. C3U: 3.9 ± 2.3 min, P < 0.05. Corresponding to the fluoroscopy time, the fluoroscopy dose was also reduced significantly. ③ In the C3U group, the fluoroscopy during VAs ablation was lower than that of other arrhythmias (P < 0.05).ConclusionThe usage of the “novel image integration technology” CARTO Univu might be safe and effective in RFCA for a wide spectrum of tachyarrhythmias in children, which could significantly reduce fluoroscopy and has a more prominent advantage for VAs ablation.

Keywords