Sensors (Oct 2009)

Identification of Tea Storage Times by Linear Discrimination Analysis and Back-Propagation Neural Network Techniques Based on the Eigenvalues of Principal Components Analysis of E-Nose Sensor Signals

  • Huichun Yu,
  • Yongwei Wang,
  • Jun Wang

DOI
https://doi.org/10.3390/s91008073
Journal volume & issue
Vol. 9, no. 10
pp. 8073 – 8082

Abstract

Read online

An electronic nose (E-nose) was employed to detect the aroma of green tea after different storage times. Longjing green tea dry leaves, beverages and residues were detected with an E-nose, respectively. In order to decrease the data dimensionality and optimize the feature vector, the E-nose sensor response data were analyzed by principal components analysis (PCA) and the five main principal components values were extracted as the input for the discrimination analysis. The storage time (0, 60, 120, 180 and 240 days) was better discriminated by linear discrimination analysis (LDA) and was predicted by the back-propagation neural network (BPNN) method. The results showed that the discrimination and testing results based on the tea leaves were better than those based on tea beverages and tea residues. The mean errors of the tea leaf data were 9, 2.73, 3.93, 6.33 and 6.8 days, respectively.

Keywords