Echo Research and Practice (Jul 2024)

Reproducibility of semi-quantitative assessment of aortic valve calcification and valve motion on echocardiography: a small-scale study

  • D. Balian,
  • B. Koethe,
  • S. Mohanty,
  • Y. Daaboul,
  • S. H. Mahrokhian,
  • J. Frankel,
  • J. Li,
  • A. Kherlopian,
  • B. C. Downey,
  • B. Wessler

DOI
https://doi.org/10.1186/s44156-024-00050-3
Journal volume & issue
Vol. 11, no. 1
pp. 1 – 5

Abstract

Read online

Abstract Background Aortic stenosis (AS) is the most common degenerative valve disease in high income countries. While hemodynamic metrics are commonly used to assess severity of stenosis, they are impacted by loading conditions and stroke volume and are often discordant. Anatomic valve assessments such as aortic valve calcification (AVC) and valve motion (VM) during transthoracic echocardiography (TTE) can offer clues to disease severity. The reliability of these semi-quantitatively assessed anatomic imaging parameters is unknown. Methods This is a retrospective study of semi-quantitative assessment of AVC and valve VM on TTE. TTEs representing a range of AS severities were identified. The degree of calcification of the aortic valve and the degree of restricted VM were assessed in standard fashion. AVC scores and valve motion were assessed by readers with varied training levels blinded to the severity of AS. Correlation and inter-reader reliability between readers were assessed. Results 420 assessments (210 each for AVC and VM) were collected for 35 TTEs. Correlation of AVC for imaging trainees (fellows and students, respectively), ranged from 0.49 (95% CI 0.18–0.70) to 0.62 (95% CI 0.36–0.79) and 0.58 (95% CI 0.30–0.76) to 0.54 (95% CI 0.25–0.74) for VM. Correlation of anatomic assessments between echocardiographer-assigned AVC grades was r = 0.76 (95% CI 0.57–0.87)). The correlation between echocardiographer-assigned assessment of VM was r = 0.73 (95% CI 0.53–0.86), p < 0.00001 for both. For echocardiographer AVC assessment, weighted kappa was 0.52 (0.32–0.72), valve motion weighted kappa was 0.60 (0.42–0.78). Conclusion There was good inter-reader correlation between TTE-based semi-quantitative assessment of AVC and VM when assessed by board certified echocardiographers. There was modest inter-reader reliability of semi-quantitative assessments of AVC and VM between board certified echocardiographers. Inter-reader correlation and reliability between imaging trainees was lower. More reliable methods to assess TTE based anatomic assessments are needed in order to accurately track disease progression. Clinical Trial Number STUDY00003100.

Keywords