Arquivos Brasileiros de Cardiologia (May 2007)

O teste ergométrico é factível, eficaz e custo-efetivo na predição de eventos cardiovasculares no paciente muito idoso, quando comparado à cintilografia de perfusão miocárdica In comparison to the myocardial perfusion scintigraphy, a treadmill stress test is a viable, efficient and cost effective option to predict cardiovascular events in elderly patients

  • Luciano Janussi Vacanti,
  • Andrei Carvalho Sposito,
  • Luciano Séspedes,
  • Maíra Sarpi,
  • José Antonio F. Ramires,
  • Anna E. Bortnick

DOI
https://doi.org/10.1590/S0066-782X2007000500006
Journal volume & issue
Vol. 88, no. 5
pp. 531 – 536

Abstract

Read online

OBJETIVO: Definir o valor prognóstico e a custo-efetividade do teste ergométrico (TE) em comparação à cintilografia de perfusão miocárdica com dipiridamol (DIP) em indivíduos com > 75 anos de idade. MÉTODOS: Foram avaliados, consecutiva e prospectivamente, 66 pacientes (40% homens), com média de idade de 81 ± 5 anos. Desses pacientes, 57% eram hipertensos, 38% eram dislipidêmicos e 28%, diabéticos. O protocolo de Bruce para rampa foi adaptado, obtendo-se o valor prognóstico do TE pelo escore de Duke. RESULTADOS: A duração do TE, o porcentual da freqüência cardíaca máxima preconizada e o duplo produto no pico do exercício foram, respectivamente, de 7 ± 3 minutos, 95 ± 9% e 24.946 ± 4.576 (bpm x mmHg). O TE e a DIP apresentaram resultados positivos para isquemia miocárdica similares (21% vs 15%, respectivamente). A concordância entre os testes foi de 88% (Kappa 0,63, p OBJECTIVE: To define the prognostic value and cost-effectiveness of the treadmill stress test (TST) in comparison to the dipyridamole myocardial perfusion scintigraphy (DIP), in individuals >75 years of age. METHODS: Consecutive and prospective assessment of 66 patients (40% male) aged 81 ± 5 years of which 57% were hypertensive, 38% had dyslipidemia and 28% were diabetics. The Bruce protocol was adapted for a tilt treadmill and the TST prognostic value was obtained using the Duke treadmill score. RESULTS: The TST duration, recommended maximum heart rate percentage and double product at peak exercise were respectively: 7 ± 3 minutes, 95 ± 9% and 24,946 ± 4,576 (bpm x mmHg). The TST and DIP presented similar positive results for myocardial ischemia (21% vs 15%, respectively). The correlation between the tests was 88% (Kappa 0.63, p<0.01). During 685 ± 120 days of follow-up, nine major events occurred: 6 deaths, 2 acute coronary syndromes and 1 myocardial revascularization. The variables associated with the major events were: age (83 ± 6 vs 80 ± 4 years; p=0.048), male gender (78% vs 33%; p=0.02), ST segment depression (1 ± 1 mm vs 0.25 ± 0.6 mm; p= 0.01), high or intermediate risk determined by the Duke treadmill score - combined in one group (44% vs 2%; p=0.001) and abnormal DIP (44% vs 10%, p= 0.02). CONCLUSION: For this elderly population, the TST was an efficient and viable option with a similar diagnostic value in comparison to the DIP. However, the TST was more accurate in the prediction of major events and offers a lower cost.

Keywords