Scientific Reports (Nov 2023)
Relationship between CGM-derived nocturnal hypoglycemia and subjective sleep quality in people with type 1 diabetes
Abstract
Abstract This pilot study explores the relationship between nocturnal hypoglycemia (NH) and subjective sleep quality in people with type 1 diabetes (T1D). Twenty-seven adults with T1D wore a Freestyle Libre Pro CGM and recorded subjective sleep quality daily, as assessed by a single Likert scale question. Frequency, duration, area under the curve (AUC) of NH (00:00–06:00) defined as sensor glucose below threshold (< 3.9 mmol/L; < 3 mmol/L) for ≥ 15 min, nocturnal mean glucose, Time in Range (3.9–10 mmol/L), and coefficient of variation were calculated. Twenty-seven adults, 18 (66.7%) women, with median (IQR) age of 27 (26, 32) years and HbA1c of 7.6 (7.1, 8.1) participated. Nights with NH < 3.9 mmol/L resulted in a lower (worse) sleep score than nights without NH [Mean (SD): 3.3 (1.2) vs 3.5 (1.0), p = 0.03). A higher frequency and longer duration but not AUC [adjusted OR (95% CI) 0.52 (0.38, 0.72), 0.961 (0.932, 0.991), 0.999 (0.998, 1.001) respectively)], of NH < 3.9 mmol/L, were associated with a lower sleep score. NH < 3.0 mmol/L metrics were not associated with sleep quality. Recurrent NH < 3.9 mmol/L, rather than prolonged NH < 3.0 mmol/L, seems associated with subjective sleep quality, implying that those with the highest burden of NH are likely unaware of it.