Measurement Science Review (Apr 2021)
Testing of Selected Accuracy Parameters for the Single Axis Positioner at the Automated Workplace
Abstract
Although some authors realized various measurement techniques and relevant standards in the experimental verification, the existing contributions still did not mention more complex automated workplaces with industrial robotic arm participation. To solve this, we provide a different view of the interconnection between individual devices (positioner, robot, etc.) controlled by third-party methods (Siemens products). Also, to obtain the necessary effectiveness, we tested and verified selected accuracy parameters for the participating device component (positioner). The proposed work tries to fulfill expectations for a precise welding technology (to ensure simultaneous movements of both the industrial robotic arm and positioner) to achieve higher quality and productivity. However, the components are from different manufacturers.
Keywords